TR100-THC-G

SKU: TR100THCG
$433.32

This item is IN STOCK

Current Stock: 49

Details

Details

Wall Module with Temperature setpoint: Temperature, Humidity and CO2 sensors

****

Product data sheet

Click Here

****

Protocols and compatibility

Modbus™ RTU, BACnet™ MS/TP, and Sylk™ enable future firmware updates and enhanced functionality. The Honeywell TR100 works with Honeywell and third‑party controllers and is not based on proprietary protocols. Its capacitive touchscreen interface allows easy configuration with minimal installation training, and embedded help screens make setup intuitive.

Part Numbers Description

Part Numbers

TR100 Wall Module Part Numbers
Part NumberSensorsCommunication ProtocolPower
TR100-T-GTemperatureModbus™ RTU, BACnet™ MS/TP, Sylk™24 VAC/VDC or Sylk™
TR100-TH-GTemperature, HumidityModbus™ RTU, BACnet™ MS/TP, Sylk™24 VAC/VDC or Sylk™
TR100-THC-GTemperature, Humidity and CO₂Modbus™ RTU, BACnet™ MS/TP, Sylk™24 VAC/VDC or Sylk™
Accessories / Replacement Parts*
Part NumberDescription
TRTC-DECOPLATE-1TR100 deco plate.
Weight and Dimensions
ParameterSpecification
Dimension (L × W × H)3.93 × 1.02 × 4.47 inches (100 × 26 × 113 mm)
Weight0.52 lbs. (238 grams)

TR100 Wall Module — Technical Specification

Power Characteristics

ParameterSpecification
Power SupplyRated Voltage: 24 VAC 50/60 Hz
Working Voltage Range: (1) 24 VAC 50/60 Hz, 20–30 VAC
(2) 24 VDC, 20–30 VDC
(3) Power over Sylk™ communication
Power Consumption (Display ON)Max. 3.2 VA @ 24 VAC (0.8–0.9 W @ 24 VDC/Sylk™M)
Supported Devices on Sylk™MSylk™ Powered: Emulate TR42/TR7x series, support max (1) device.
Connect external 24VAC/VDC supply if multi-devices work under one Sylk bus.

Display

ParameterSpecification
Display Type16 BPP TFT display with CTP
Resolution320 × 240 pixels
Active Display Area2.4" diagonally
BacklightLCD (Dimmable)
LED Color RingBlue (Cooling), Orange (Heating)

Onboard Sensor

ParameterSpecificationDetails
TemperatureResolution1 ºF (0.5 ℃)
Accuracy±1.5 ºF (0.8 ℃) from 32–122 ºF (0–50 °C)
±0.6 ºF (0.35 ℃) with 95% confidence from 60–85 ºF (15–30 °C)
HumidityResolution1 % RH
Accuracy±3 % RH from 20–80% RH @ 25 ℃
CO₂Measure Range400–5000 ppm
Sensor Output Resolution1 ppm
Accuracy±(50 ppm ± 2.5% reading) @ 400–1000 ppm
±(50 ppm ± 3% reading) @ 1001–2000 ppm
±(40 ppm ± 5% reading) @ 2001–5000 ppm

Electrical Characteristics

ParameterSpecification
Rated Impulse Voltage500 V
Construction of ControlIndependently Mounted Control
Operation MethodType 1 Action
Pollution Degree2
Purpose of ControlOperating Control

Wire Specification

ParameterSpecification
Wire Gauge14–26 AWG (0.2–1.5 mm² solid/stranded, max 2.5 mm² solid)
Wire TypeCopper

Operating Environment

ParameterSpecification
Ambient Operating Temperature32–122 ºF (0–50 °C)
Ambient Operating Humidity10–90 % RH (non-condensing)
Storage Temperature-40–150 ºF (-40–65.5 °C)
Protection ClassIP20

Communication

ParameterSpecification
Sylk™Honeywell Sylk™
BACnet™ MS/TP9.6, 19.2, 38.4, 57.6, 76.8, 115.2 Kbps
Modbus™ RTU0.3–115.2 Kbps

Controller Compatibility

The TR100 is open protocol and connects to controllers using BACnet™ MS/TP, Modbus™ RTU, and Sylk™.

BACnet™ MS/TP and Modbus™ RTU: All Honeywell and third-party controllers supporting standard communications.

Sylk™ Optimizer Supervisor: Spyder classic, Stryker, CIPer Model 30, Optimizer Unitary

Comfort Point™ Open (CPO): CPO-Rxx, CPO-VAV2A, Optimizer Unitary, Optimizer VAV

Honeywell TR100 Wall Module — Replaceability & Feature Comparison

TR100 Wall Module — Replaceability & Feature Comparison

Replaceability

TR42, TR42-H, TR42-CO₂, TR42-H-CO₂, TR75, TR75-H, TR71, TR71-H, TR71-TH, TR120, TR120-H, TR120-TH wall modules wired to controllers can be directly replaced by TR100-T-G, TR100-TH-G, or TR100-THC-G. Simply remove the old wall module and install the new one (including new backplate). Backplate sizes and mounting holes are identical.

The TR100 accepts TR42 or TR75 file configurations (proxy file) downloaded from the existing controller and provides the same configuration and functionality with a modern touchscreen interface. TR100 modules can directly accept TR42 or TR75 application downloads without modifications in the controller or engineering tool.

TR100 feature comparison

Feature comparison for TR75 emulation, TR42 emulation, and TR100 (BACnet™ MS/TP / Modbus™ RTU)
FeatureTR75 emulationTR42 emulationTR100 (BACnet™ MS/TP / Modbus™ RTU)
TR100-T-GTR100-TH-GTR120TR75TR71TR100-T-GTR100-TH-GTR100-THC-GTR42TR100-T-GTR100-TH-GTR100-THC-G
Color touch
Usability/displaySwipe & touchSwipe & touchTouchPredefined buttonsPredefined buttonsSwipe & touchSwipe & touchSwipe & touchPredefined buttonsSwipe & touchSwipe & touchSwipe & touch
Sensing: temperature
Sensing: humidity
Sensing: CO₂
Temperature setpoint
Override
Fan
Customizable parameters☒ (limited)
VAV balancing☒ (limited)
Schedule access
User management levels222222222444
Communication protocolSylk™Sylk™Sylk™Sylk™Sylk™Sylk™Sylk™Sylk™Sylk™BACnet™ MS/TP / Modbus™ RTUBACnet™ MS/TP / Modbus™ RTUBACnet™ MS/TP / Modbus™ RTU
Alarms
Firmware updateswith HON Toolswith HON Toolswith HON Tools

Symbols: ☒ = supported, − = not supported or not applicable.