TE-6310F-1

SKU: TE6310F1
$67.26

This item is IN STOCK

Current Stock: 2

Details

Details

Controlco Product Information Tabs
Product DetailsSpecificationsDownloads

Product Information


Flush Mount Temperature Sensor is a device that measures air temperature, via a temperature sensing element, thermally bonded to a metal electrical box cover. The sensor is designed for direct connection to a supervisory controller.


The TE-6300 Temperature Sensor line provides economical solutions for a wide variety of temperature sensing needs, including wall-mount, outdoor-air, duct, strap-mount, well-insertion, duct-averaging, and VAV Modular Assembly (VMA) flange-mount duct-probe applications. The TE-6300 line offers both a metal and a plastic enclosure for the most popular models.


Features and Benefits


Each sensor is packaged with the necessary mounting accessories to maximize ordering and installation ease and to reduce both commissioning time and cost.


• Brushed Stainless Steel Mounting Plate—Offers a durable, aesthetically pleasing design.
• Single Assembly Ordering—Simplifies ordering; provides a complete assembly in one box.
• Models Featuring an Integral National Pipe Thread (NPT) Adaptor—Increase sensor connection strength, which eliminates the need for a special adaptor.
• Models with a Stainless Steel Sensor Probe— Protect the sensor while increasing corrosion resistance.
• Metal Enclosure (TE-63xxE, TE-63xxM, and TE-63xxV Models)—Meets plenum requirements.
• Models Featuring a Retainer for the Sensor Holder—Allow you to lock the sensor holder into the conduit box.
• Low Profile Flush Mount Design (TE-63xxF Models)—Provides a tamper-proof installation ideally suited for schools, sporting complexes, retailers, prisons, and more.
• Full Line of Versatile Sensors—Supports all your temperature sensing needs from a single supplier: wall-mount, outdoor-air, duct, ductaveraging, strap-mount, well-insertion, and flange-mount duct-probe.

All TE-6300 Series Temperature Sensors are twowire, passive, resistance-output devices.


Integrated Actuator Specifications

Specifications


SpecificationDescription
Sensor Accuracy1k ohm nickel±0.34F° at 70°F (±0.19C° at 21°C)
1k ohm nickel averaging±3.4F° at 70°F (±1.9C° at 21°C)
1k ohm platinum Class A (TE-635xx)EN 60751 Class A, ± [0.15 + 0.002 * | T °C |], ±0.19C° at 21°C (±0.35F° at 70°F)
100 ohm platinum Class A
1k ohm platinum Class B (TE-632xx)EN 60751 Class B, ± [0.30 + 0.005 * | T °C |], ±0.41C° at 21°C (±0.73F° at 70°F)
100 ohm platinum averaging±1.0°Fat 70°F (± 0.58°C at 21°C)
1k ohm platinum averaging
2.2k ohm thermistor± 0.36°F ( ± 0.2°C) in the range: 32 to 158°F (0 to 70°C)
10k ohm thermistor± 0.9°F ( ± 0.5°C ) in the range: 32 to 158°F (0 to 70°C)
Sensor Temperature Coefficient1k ohm nickelApproximately 3 ohms/F° (5.4 ohms/C°)
1k ohm nickel averaging
1k ohm platinum Approximately 2 ohms/F° (3.9 ohms/C°) 3,850 ppm/K
100 ohm platinum averagingApproximately 0.2 ohms/F° (0.39 ohms/C°)
1k ohm platinum averagingApproximately 2 ohms/F° (3.9 ohms/C°)
2.2k ohm thermistorNonlinear, negative temperature coefficient (NTC)
10k ohm thermistor Nonlinear NTC, Johnson Controls Type II
Electrical ConnectionTE-63xxE22 AWG (0.6 mm diameter) x 6 in. (152 mm) long
TE-63xxM
TE-63xxP
TE-63xxF22 AWG (0.6 mm diameter) x 12 ft (3 m) braided-copper wires, low voltage insulation, half-stripped end
TE-63xxP nickel averaging18 AWG (1.0 mm diameter) x 6 in. (152 mm) long
TE-63xS22 AWG (0.6 mm diameter) x 10 ft (3 m) long plenum-rated cable
TE-63xxA22 AWG (0.6 mm diameter) x 10 ft (3 m) long plenum-rated cable, with 2-position plug terminal block for 1/4 in. (6.35 mm) external tab terminals on 0.197 in. (5 mm) centers
TE-63xxV
Materials
ProbesNickel averaging: 0.094 in. (2.4 mm) outside diameter (O.D.) copper tubing Nickel averaging adaptor: 0.25 in. (6.35 mm) O.D. brass Platinum averaging probe: 0.19 in. (4.8 mm) aluminum tubing All others: 0.25 in. (6.35 mm) O.D. stainless steel
TE-63xxAMounting adaptor plate and gland: thermoplastic
TE-63xxFFlush mount: stainless steel
TE-63xxMEnclosure: corrosion-protected steel Well sensor holder: 0.875 in. (22.2 mm) hex brass
TE-63xxPConduit box and shield: rigid thermoplastic Mounting plate : aluminum Sensor holder: rigid thermoplastic Wall mount base plate: corrosion-protected steel Wall mount cover: rigid thermoplastic (white) Wall mount face plate: brushed aluminum
TE-63xxEMounting flange: stainless steel
TE-63xxV
Operating Conditions
TE-63xxA-50 to 140°F (-46 to 60°C)
TE-63xxF32 to 104°F (0 to 40°C)
TE-63xxE-50 to 220°F (-46 to 104°C)
TE-63xxM
TE-63xxPEnclosure: -50 to 122°F (-46 to 50°C) Sensor probe: -50 to 220°F (-46 to 104°C)
TE-63xSSensor probe: -50 to 220°F (-46 to 104°C) Wire harness: -50 to 122°F (-46 to 50°C)
TE-63xxV
Shipping Weight
TE-63xxA0.2 lb (0.09 kg)
TE-63xxE
TE-63xxF0.25 lb (113.4 kg)
TE-63xxMDuct averaging: 0.9 lb (0.41 kg) Duct mount: 0.4 lb (0.18 kg) Well insertion: 0.5 lb (0.23 kg)
TE-63xxPDuct averaging: 0.5 lb (0.23 kg) Duct mount: 0.4 lb (0.18 kg) Outdoor air: 0.5 lb (0.23 kg) Wall mount: 0.2 lb (0.09 kg) Well insertion: 0.35 lb (0.16 kg)
TE-63xSStrap mount: 0.2 lb (0.09 kg)
TE-63xxVDuct averaging: 0.7 lb (0.32 kg) Duct mount: 0.2 lb (0.09 kg
Dimensions (H x W x D)TE-63xxA2.17 in. (55 mm) diameter plus 4 or 8 in. (102 or 203 m) element
TE-63xxEDuct mount: 2.5 x 1.50 in. (57 x 38 mm) plus 2, 6, 8, or 12 in. (51, 152, 203, or 305 mm) element
TE-63xxFFlush mount: 4-1/2 x 2-3/4 in. (114 x 70 mm)
TE-63xxMDuct averaging: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 8 or 17 ft (2.4 or 5.2 m) element Duct mount: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 4, 8, or 18 in. (102, 203, or 457 mm) element Well insertion: 1.87 x 1.87 x 1.80 in. (47.5 x 47.5 x 45.8 mm) plus 6 or 8 in. (152 or 203 mm) element
TE-63xxPDuct averaging: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 8, 10, 17, or 20 ft (2.4, 3.0, 5.2, or 6.1 m) element Duct mount: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 6 or 8 in. (152 or 203 mm) probe Outdoor air: 5.97 x 3.47 x 4.46 in. (152 x 88 x 113 mm) Wall mount: 2.09 x 3.12 x 1.80 in. (53 x 79 x 46 mm) Well insertion: 5.97 x 1.38 x 2.75 in. (152 x 35 x 70 mm) plus 6 or 8 in. (152 or 203 mm) probe
TE-63xSStrap mount: 0.25 in. (6.4 mm) diameter x 3.00 in. (76 mm) long
TE-63xxVDuct averaging: 2.25 x 1.50 in. (57 x 38 mm) plus 8 or 17 ft (2.4 or 5.2 m) element Duct mount: 2.25 x 1.50 in. (57 x 38 mm) plus 4 or 8 in. (102 or 203 mm) element