SFD212EG4YA07D07

SKU: SFD212EG4YA07D07
$4,454.74

Call for Availability - (510) 636-7900

Details

Details

3 HP (2.2 kW) Enclosed VFD with Full-Voltage Bypass, 460 VAC 3-Phase, UL Type 1, Drive Input Disconnect and Full Text Keypad

NEMA 1, 460V 3-phase VFD with bypass, drive input disconnect and text keypad. The text keypad uses the RJ-45 port, so Modbus isn't available there.

Key Features

  • Output current: 4.8 A
  • Input current: 4.9 A
  • Bypass overload relay range: 4 to 6 A
  • Control power transformer: 120 VAC, 100 VA, fused
  • Short-circuit rating: 100,000 A symmetrical

Product Specifications

ManufacturerSchneider Electric
ModelSFD212EG4YA07D07
SeriesS-Flex 212 enclosed drive (Square D)
Power converterAltivar 212 ATV212HU22N4
Horsepower rating3 HP, variable torque
Kilowatt rating2.2 kW
Input voltage460 VAC +/-10%, three-phase
Input frequency50/60 Hz +/-5%
Input current4.9 A
Output current4.8 A
Max transient output current5.6 A
Output voltageThree-phase, maximum equal to input voltage
Dissipated power at rated load224.7 W
Switching frequencySelectable 6 to 16 kHz; factory setting 12 kHz
Rating conditions12 kHz switching frequency, 104 deg F (40 deg C) ambient
Short-circuit rating100,000 A symmetrical
Displacement power factorApproximately 0.96
Frequency range0.5 to 200 Hz (factory setting 60 Hz maximum)
Current limit110% of drive full load current for 60 s
Speed referenceVIA: 4-20mA (factory setting), 0-20mA or 0-10 VDC; VIB: 0-10 VDC
Analog outputConfigurable (FM)
Frequency resolution0.0048 Hz (11 bits) on analog reference
Speed accuracy+/-10% of nominal slip without speed feedback, 20 to 100% of motor rated torque
EfficiencyTypically greater than 95%
Acceleration and deceleration ramps0.1 to 3200 s in 0.1 s steps; factory setting 60 s
Factory speed range15 to 60 Hz (low and high speed settings)
BypassFull-voltage bypass (power circuit Y): drive output and bypass contactors with electrical interlock
Main disconnectSquare D circuit breaker HLL36015LV
Drive output and bypass contactorsLC1D25G7
Overload relayClass 10, LRD10
Bypass overload relay range4 to 6 A
Motor protectionClass 10 overload relay in bypass plus drive internal electronic thermal protection
Power fusesClass CC, 7 A (25430-20700)
Drive input disconnectDisconnect switch between the main disconnect and the drive (A07)
Control power transformer120 VAC, 100 VA, fused
Selector switchesAFC-Off-Bypass (Series D); Hand-Off-Auto and AFC-Bypass (Series E)
Pilot lightsPower On (red) and Bypass Run (green), 120 VAC LED
Smoke purge120 VAC signal at TB1-17/18 transfers the motor to line power
Damper controlOpen-damper relay contact (TB1-19/20) and damper end switch input
Auxiliary contactsSystem run (NO, drive or bypass); AFC trip; Form C AFC fault
Freeze/firestat interlockInput for user-supplied NC interlock (factory jumper installed)
Local/remoteConfigurable on the enclosed drive
CommunicationRJ-45 Modbus port used by the D07 keypad; factory set for terminal control
KeypadFull text graphic keypad, door mounted, 8 languages (D07)
EnclosureUL Type 1, general indoor (ventilated), plenum rated
Frame sizeA
MountingWall mount
Control terminals24 to 16 AWG, one wire per terminal, 5.3 to 7.1 lb-in
Operating temperature14 to 104 deg F (-10 to 40 deg C)
Storage temperature-13 to 158 deg F (-25 to 70 deg C)
Humidity95% with no condensation or dripping water (IEC 60068-2-3)
Altitude3,300 ft (1000 m) without derating; derate current 1% per additional 330 ft (100 m) up to 10,000 ft (3000 m)
Pollution degree2 (NEMA ICS-1, IEC 60664-1)
Vibration (power converter)1.5 mm peak to peak from 3 to 13 Hz; 1 g from 13 to 150 Hz (IEC 60068-2-6)
Shock (power converter)15 g, 11 ms
ApprovalsUL Listed per UL 508C, Class 10 overload protection
StandardsNEMA ICS, NFPA and IEC; manufactured under ISO 9001; AHRI certified
Weight52 lb (23.5 kg), varies with options