22UTH-550X

SKU: 22UTH550X
$434.70

Call for Availability - (510) 636-7900

Details

Details

22UTH-550X Outdoor Humidity and Temperature Sensor, Modbus RTU, Radiation Shield

Two 0-5V/0-10V outputs (temp and humidity) in addition to Modbus; ranges set over the network.

Shield keeps rain and radiated heat from roofs and nearby surfaces off the sensing elements.

Key Features

  • Nominal voltage: 24 VAC/DC
  • Operating condition airflow: max. 40 ft/s (12 m/s)

Product Specifications

ManufacturerBelimo
Model22UTH550X (22UTH-550X)
CommunicationModbus RTU
Output signal active temperature0 to 5 V, 0 to 10 V
Output signal active humidity0 to 5 V, 0 to 10 V
Nominal voltage24 VAC/DC
Nominal voltage range19 to 29 VAC / 15 to 35 VDC
Power consumption AC4.3 VA
Power consumption DC2.3 W
Electrical connectionPluggable spring-loaded terminal block max. 2.5 mm2
Cable entryCable gland with strain relief 2x dia. 6 mm (1/2 in. NPT conduit adapter included)
ApplicationAir
Voltage output2 x 0 to 5 V, 0 to 10 V, min. resistance 10k
Output signal active noteoutput 0 to 5/10 V with jumper adjustable
Measured valuesrelative humidity; Absolute humidity; Dew point; Enthalpies; Temperature
Measuring range temperatureAdjustable via Modbus -5 to 175 deg F (-20 to 80 deg C) (default setting)
Accuracy temperature+/-0.5 deg F @ 77 deg F (+/-0.3 deg C @ 25 deg C)
Long-term stability temperature+/-0.09 deg F p.a. @ 70 deg F (+/-0.05 deg C p.a. @ 21 deg C)
Time constant temperature (63%) in the roomTypical 351 s @ 0 m/s
Sensing element technology humidityPolymer-based capacitive sensor with stainless steel wire mesh filter
Measuring range humidityadjustable via Modbus; Default setting: 0 to 100% RH
Measuring range absolute humidityadjustable via Modbus default setting: 0 to 80 g/m3
Measuring range enthalpyadjustable via Modbus default setting: 0 to 85 kJ/kg
Measuring range dew pointadjustable via Modbus default setting: -5 to 175 deg F (-20 to 80 deg C)
Accuracy humidity+/-2% between 0 to 80% RH @ 77 deg F (25 deg C)
Long term stability humidity+/-0.3% RH p.a. @ 70 deg F (21 deg C) @ 50% RH
Time constant humidity (63%) in the roomTypical 16 s @ 0 m/s
Protection class IEC/ENIII, Safety Extra-Low Voltage (SELV)
Power source ULClass 2 Supply
Degree of protection IEC/ENIP65
Degree of protection NEMA/ULNEMA 4X
EnclosureUL Enclosure Type 4X
EU ConformityCE Marking
Certification IEC/ENIEC/EN 60730-1
Quality StandardISO 9001
UL 2043 CompliantSuitable for use in air plenums per Section 300.22(C) of the NEC and Section 602 of the IMC
Type of actionType 1
Rated impulse voltage supply0.8 kV
Pollution degree3
Ambient humidityshort-term condensation permitted
Ambient temperature-30 to 120 deg F (-35 to 50 deg C)
Fluid humidityshort-term condensation permitted
Fluid temperature-30 to 122 deg F (-35 to 50 deg C)
Operating condition airflowmax. 40 ft/s (12 m/s)
HousingCover: PC, orange; Bottom: PC, orange; Seal: NBR70, black; UV resistant; UL94 5VA
Cable glandPA6, black
Weather protectionWeather and radiated heat shield (radiation shield)
Parts includedCable gland dia. 6 to 8 mm, dowels, screws, 1/2 in. NPT conduit adapter