Fireye

717 Products

MED6
Daughter board with local reset switch, display output, remote reset, and communicat
MED7
Daughter board with local reset switch, communications.
MED8
Daughter board with normally open relay, for use with MEC320TS
MED9
Daughter board with normally closed relay, for use with MEC320TS
MEDC2
Amplifier for use with dry contact input from 85UVF-WR flame scanner, 0.30 sec FFRT.
MEIR1
Infrared amp, 0.8 sec FFRT. Use with 48PT2 scanner.
MEIR4
Infrared amp, 3 sec FFRT. Use with 48PT2 scanner.
MEP100
Programmer, Relight function, 10 sec PTFI.
MEP100P
Programmer, Relight operation, 10 sec PTFI, 15 sec post purge.
MEP101
Programmer, Relight function, allow flame signal until 60 seconds after interlock ci
MEP102
Programmer, Non-recycle on flame fail, 5 second PTFI.
MEP103
Programmer, Fixed 10 sec SISP*, 10 sec MTFI, re-try once on pilot failure, fixed 30
MEP104
Programmer, Non-recycle on flame fail, 10 second PTFI.
MEP105
Programmer, Non-recycle on flame fail, lockout on air-flow open with flame present,
MEP106
Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interrupti
MEP107
5 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural dra
MEP108
Non-recycle operation, 0 sec purge, 15 second PTFI, 10 second post purge, no FM Appr
MEP109
Programmer, Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed
MEP130
Programmer, Relight operation, 30 sec PTFI, no agency approvals
MEP141
Programmer, 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec p
MEP149
Programmer, 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec p
MEP230
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP230H
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP235
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP236
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP237
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP238
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP290
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, prove
MEP300
Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fai
MEP304
Programmer, 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving, 10 sec MTFI, inte
MEP397
Programmer, 15 sec purge, provides interrupted ignition, interrupted pilot, non re-c
MEP437
Programmer, Valve proof of closure, selectable purge, PTFI timing, intermittent or i
MEP536
Same as MEP560 without pilot stabilization period. Will not lockout on air flow open
MEP537
Same as MEP536 except provides one recycle on main flame fail.
MEP560
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP561
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post
MEP562
Programmer, Selectable TFI timing, purge timing, post purge, prove open at start, 8
MEP564
Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.
MEP696
Programmer, provides selectable PTFI, selectable baud rate, and selectable recycle /
MEP697
Programmer Selectable TFI timing, purge timing, post purge, prove open at start, and
MERT1
Flame rect amp. 0.8 sec FFRT. Use with 69ND, 45CM.
MERT4
Flame rect amp. 3 sec FFRT. Use with 69ND, 45CM.
MEUV1
UV amp, 0.8 sec FFRT. Use with UV1, UV2, 45UV3.
MEUV4
UV amp, 3 sec FFRT. Use with UV1, UV2, 45UV3.
MEUVS1
UV self check amp, 0.8 sec FFRT. Use with 45UV5-1008, -1009.
MEUVS4
UV self check amp, 3 sec FFRT. Use with 45UV5-1008, -1009.
MP100
Programmer, Relight function.
MP100E
Programmer, Relight function. For MC230, MC120E only.