CO Gas Detector, 0-250 ppm, with Remote NO2 Unit, 0-10 ppm, BACnet MS/TP, 3 Relays, LCD

Needs 24 VDC or 24 VAC power at both the main and remote units; the AC supply must not be grounded. Works indoors only, despite its NEMA 4X enclosures.

Key Features

  • Mounting height: Main unit: Mid: 4.0 to 6.0 ft (1.20 to 1.83 m) above floor; remote unit: Low: 0.5 to 1.5 ft (0.15 to 0.46 m) above floor
  • Sensor life: Main unit: 7 years typical (CO); remote unit: 2 to 3 years typical (electrochemical)

Product Specifications

ManufacturerACI
ModelB6-CO/NO2-10P
ACI item number146119
Gas detectedMain unit: carbon monoxide (CO); remote unit: nitrogen dioxide (NO2)
Sensor typeMain unit: electrochemical (toxic); remote unit: electrochemical (toxic)
Measurement rangeMain unit: CO 0 to 250 ppm; remote unit: NO2 0 to 10 ppm
Operating tempMain unit: -4 to 122 deg F (-20 to 50 deg C); remote unit: -4 to 122 deg F (-20 to 50 deg C)
Coverage areaMain unit: 7500 sq ft (696.7 sq m) or 49 ft (14.9 m) radius; remote unit: 7500 sq ft (696.7 sq m) or 49 ft (14.9 m) radius
Mounting heightMain unit: Mid: 4.0 to 6.0 ft (1.20 to 1.83 m) above floor; remote unit: Low: 0.5 to 1.5 ft (0.15 to 0.46 m) above floor
Remote unitSensor only; its reading shows on the main unit LCD
Supply voltage24 VDC nominal (18 to 30 VDC) or 24 VAC nominal (15 to 24 VAC) at the main and remote units; AC power must not be grounded
Communication protocolRS-485 serial BACnet MS/TP (master and slave; default master)
Baud rates9600, 19200, 38400, 76800 bits/second (default 38400)
Analog outputsNone
DisplayLCD graphic display with backlight (TWA, STEL, and concentration)
KeypadThree capacitive touch keys
RelaysThree SPDT (Form C) dry contacts, 1.0A max at 30 VDC or 0.3A max at 125 VAC (resistive)
Relay lifeMechanical 50,000,000 operations minimum at 36,000 operations/hour; electrical 200,000 operations minimum at rated load
Status LEDsTwo green (Tx/Rx communication); three relay LEDs (relays 1, 2, and 3)
Buzzer80 dB at 3.94 in. (10 cm), 2700 Hz, 3 programmable tones
Warm-up time24 hours (allow 24 hours before calibrating after installation)
Fuse protection0.750A polyswitch; resets after the fault is cleared and power is removed
Supply current / power0.3A maximum / 8.4 VA
EnclosurePolycarbonate (Lexan), UL94 V-0, NEMA 4, 4X, 12, and 13 (IP66)
Operating environmentIndoor use only
Enclosure knockouts3/4 in. knockouts (accept 1/2 in. conduit fittings)
Operating humidity5 to 95% RH, non-condensing
Operating atmospheric pressure14.696 psi (1.0132 bar) +/-10%; verify accuracy and recalibrate when installed above 3000 ft
Recommended storage32 to 68 deg F (0 to 20 deg C), 5 to 95% RH non-condensing
Wiring connectionsDe-pluggable screw terminal blocks, 16 to 24 AWG shielded twisted pair
Communications cableBelden 9841 or equivalent, 120 ohm
Terminal block torque0.37 ft-lb (0.502 Nm) nominal
Sensor lifeMain unit: 7 years typical (CO); remote unit: 2 to 3 years typical (electrochemical)
Unit shelf lifeMain unit: 6 months from date of purchase; remote unit: 6 months from date of purchase
Recommended maintenanceMain unit: Accuracy and bump test every 6 months or as required by code; remote unit: Accuracy and bump test every 6 months or as required by code
Dimensions (L x W x H)Main and remote unit, each 5.91 x 3.54 x 2.56 in. (150 x 90 x 65 mm)
Warranty2-year limited; electrochemical sensor module 6 months